A large part of Yonkers cools with a box in a window or a sleeve in a wall. Pick what it is doing and this page tells you what that usually means — and who is actually in a position to fix it, which in a rented apartment is the question that matters.

Before anything else

Unplug it before you touch anything inside it, and do not take the cover off. Everything suggested on this page is done from outside the cabinet — a filter, a plug, a window seal, a drain path. A window unit contains a compressor, a capacitor that holds a charge after it is unplugged, and a fan that starts without warning. None of that is a home repair.

It runs, but the room never gets cool

Often not worth a service call
The filter is grey, or you have never taken it out

On a window unit the filter is behind the front grille and slides out in seconds. A blocked one halves what the machine can do and it is the single most common cause of this complaint. Wash it, dry it properly, put it back.

There are gaps around the unit, or the accordion panels are torn

You are cooling the outside. The side panels and the seal at the top of the sash are the difference between a unit that copes and one that never will, and in a Yonkers apartment with old sash windows they are rarely intact after a few seasons.

It is more than about eight years old and it is on all day

Then the honest answer is that a service call on it is usually money wasted. There is very little worth repairing inside a window unit at this age, and the parts and labour approach the cost of a new one. We would rather tell you that than take the call.

A through-wall sleeve unit or a PTAC is different — those are worth servicing, and the sleeve itself is worth keeping.

Water dripping into the room

Usually you, in ten minutes
The unit is level, or tilted back into the room

A window unit is designed to sit with the outdoor end very slightly lower than the indoor end, so condensate runs away outside. Set level or tipped inwards, the water has nowhere to go but your floor. This is the cause most of the time and it is a bracket adjustment.

Water only appears on humid days, and there is ice inside

The coil is freezing and then melting faster than the pan can cope with. That is low airflow (filter, blocked coil) or low charge. Switch it off and let it thaw fully before running it again.

It is a sleeve unit or a PTAC and water is coming through the wall

Different problem. The sleeve has a drain path and a seal where it goes through the wall, and when either fails the water goes into the wall rather than out of it. In an apartment building this becomes the building’s problem, and it needs reporting rather than mopping up.

It trips the breaker, or the plug gets warm

An electrician — not us, and not you
The plug, the cord or the outlet is warm to the touch

Stop using it and unplug it. A warm plug means resistance where there should be none — a worn outlet, a loose terminal or a damaged cord — and that is how fires start. This is not something to keep an eye on.

It is on an extension lead or a power strip

Air conditioners should be plugged directly into a wall outlet. Most extension leads and strips are not rated for the current a compressor draws on start-up, and it is one of the most common things we see in apartments.

The breaker trips whenever it starts

Either the circuit is shared with too much else, or something inside the unit is drawing more than it should. Either way the next call is to a licensed electrician, not to a heating and cooling contractor and not to a handyman. If you rent, it is also a report to the building, in writing, today.

We are saying this plainly because it is the one item on this page where waiting is genuinely dangerous.

A musty smell when it starts up

You first, then us
The smell is strongest in the first minute and then fades

Growth on a permanently damp evaporator coil and in the drain pan. Extremely common, and it is what the coil does when a unit cools in short bursts and never dries out.

The filter is damp or discoloured

Wash it and dry it completely. Then run the unit on fan only for a while at the end of the day so the coil dries — that single habit prevents most of this, and it costs nothing.

It has been there for more than a season, or somebody in the room is affected

Then it needs cleaning properly rather than masking, and on a sleeve unit or a PTAC that is a job worth doing. We do not make health claims and we will not tell you what a smell is doing to anybody — that is a question for a doctor. We will tell you what is growing on the coil and what it costs to remove it.

Rattling, buzzing or a new noise

Usually you, sometimes nobody
A rattle that changes when you press on the cabinet or the sash

The unit or the window is loose. Mounting brackets, the sash lock, the side panels and the bracket bolts are all things that work loose over a season, and tightening them is the whole repair.

A clicking or slapping noise from the back in humid weather

Usually normal. Many units deliberately sling condensate from the pan onto the condenser coil to help it reject heat, and it sounds exactly like something wrong. If it happens only when it is humid and the unit is otherwise fine, it is the design working.

A grinding, screeching or metallic noise

A fan bearing or a fan hitting something. On a window unit at any age this is normally the end of it. On a PTAC or a sleeve unit it is a repair and it is worth doing before it takes the motor with it.

Cold air, but the room stays damp

Us — and it is usually sizing
It cools the room fast and then shuts off for a long time

The unit is too big for the room. Cooling and dehumidifying are two different jobs, and the second one only happens while the machine is actually running. A unit that satisfies the thermostat in four minutes never runs long enough to pull moisture out of the air.

This is the opposite of what almost everybody assumes, and it is why buying the biggest unit that fits the window is a mistake.

The room feels clammy rather than warm

Confirmation of the same thing. People describe it as “it cools but it does not feel right”, which is exactly what an oversized unit produces.

You are about to replace it

This is the one moment where a short conversation saves real money. Capacity should be matched to the room, not to the window opening, and a smaller unit that runs for longer is more comfortable and cheaper to run than a larger one that short-cycles. We will say what size the room needs and we do not sell the boxes, so there is nothing in it for us either way.

What this page is not

It is a translation, not a diagnosis, and it is not permission to open anything. If you rent, anything involving the wall, the sleeve, the wiring or the building’s equipment is a report to the managing agent rather than a repair you arrange — and putting it in writing is worth the five minutes it takes.

Worth knowing

Three things about these machines that surprise people

Bigger is worse, not better

An oversized unit short-cycles, leaves the room damp and wears itself out faster. The right size runs for long stretches and the room feels better at the same temperature.

A through-wall sleeve is an asset

The sleeve outlasts several units. When one dies, replacing it with something that fits the existing sleeve is far cheaper and far tidier than any alternative, and a good sleeve is worth maintaining.

A window unit costs more to run than a ductless head doing the same job

Materially more, and it is noisier and it blocks a window. We are not going to put a figure on your bill, because that depends on your rooms and your hours — but if you are cooling three rooms with three boxes and you own the apartment, it is worth a conversation.